PERFORMANCE DATA & PRESSURE CURVES
5-14 Revision Y05-01 Service Manual - PXD Series
5.10.2 Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL ( °C)
15 20 25
ENTERING AIR
WB OU COIL (°C)
TH PI TH PI TH PI
-10
3.02 1.42 2.90 1.51 2.79 1.58
-7 3.25 1.45 3.13 1.53 3.02 1.61
-2 3.45 1.47 3.34 1.56 3.22 1.65
2 4.20 1.54
4.03 1.64
3.85 1.73
6 5.92 1.65 5.75 1.77 5.55 1.88
10 6.44 1.75
6.27 1.87
6.10 2.00
15 6.96 1.82 6.79 1.96 6.61 2.09
20 7.33 1.88 7.16 2.04 6.96 2.19
* the above chart includes the weighted deicing infleuence.
LEGEND
TH Total Heating Capacity, kW
PI Power Input, kW
WB Wet Bulb Temp., (
o
C)
DB Dry Bulb Temp., (
o
C)
ID Indoor
OU Outdoor
5.11 Capacity Correction Factor Due to Tubing Length
5.11.1 Cooling
TOTAL TUBING LENGTH
3m
7.5m
10m 15m 20m 25m 30m 40m 50m
1.02
1
0.990 0.975 0.960 0.945 --- --- ---
* Minimum recommended tubing length between indoor and outdoor units is 3m.
5.11.2 Heating
TOTAL TUBING LENGTH
3m
7.5m
10m 15m 20m 25m 30m 40m 50m
1.03
1
1 0.997 0.992 0.988 --- --- ---
* Minimum recommended tubing length between indoor and outdoor units is 3m.