Electra OU7-24 RC Service Manual Page 36

  • Download
  • Add to my manuals
  • Print
  • Page
    / 168
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 35
5-19
PERFORMANCE DATA & PRESSURE CURVES
Revision Y06-02Service Manual - KN Series
5.14 Pressure Curves.
5.14.1 Cooling:
Discharge Pressure VS.Outdoor Temp
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
15 20 25 30 35 40 46
Outdoor Temp.(DB
o
C )
Discharge Pressure (Bar[g])
15/21(WB/DB ºC)
17/24(WB/DB ºC)
19/27(WB/DB ºC)
21/29(WB/DB ºC)
23/32(WB/DB ºC)
Suction Pressure VS.Outdoor Temp
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
15 20 25 30 35 40 46
Outdoor Temp.(DB
o
C )
Suction Pressure (Bar[g])
15/21(WB/DB ºC)
17/24(WB/DB ºC)
19/27(WB/DB ºC)
21/29(WB/DB ºC)
23/32(WB/DB ºC)
CONTENT
Page view 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 167 168

Comments to this Manuals

No comments